Sign in →

Test Code ARAV Aldosterone, Right Adrenal Vein, Serum

Reporting Name

Aldosterone, RAV

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Useful For

Investigation using right adrenal vein specimen for:

-Primary aldosteronism (eg, adrenal adenoma/carcinoma and adrenal cortical hyperplasia)

-Secondary aldosteronism (renovascular disease, salt depletion, potassium loading, cardiac failure with ascites, pregnancy, Bartter syndrome)

Method Name

Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)


Specimen Required


Patient Preparation: Spironolactone (Aldactone) should be discontinued for 4 to 6 weeks before testing. The plasma renin activity cannot be interpreted if the patient is being treated with spironolactone.

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1.8 mL

Collection Instructions:

1. See Renin-Aldosterone Studies for detailed instructions.

2. The recommended collection time is 8 a.m., after the patient is active for approximately 2 hours. Try to collect the specimen as close to that time as possible and no later than 10 a.m.

3. Centrifuge and aliquot serum into a plastic vial.


Specimen Type

Serum

Specimen Minimum Volume

1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
  Frozen  30 days
  Ambient  4 days

Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Reference Values

No established reference values.

Interpretation

A high ratio of serum aldosterone (SA) in ng/dL to plasma renin activity (PRA) in ng/mL per hour is a positive screening test result, a finding that warrants further testing. An SA:PRA ratio of 20 or higher is only interpretable with an SA of 15 ng/dL or higher and indicates probable primary aldosteronism.

 

Kidney disease, such as unilateral renal artery stenosis, results in elevated renin and aldosterone levels. Renal venous catheterization may be helpful. A positive test is a renal venous renin ratio (affected:normal) above 1.5.

 

Note: Advice on stimulation or suppression tests is available from Mayo Clinic's Division of Endocrinology and may be obtained by calling 800-533-1710.

Day(s) Performed

Monday through Friday

Report Available

2 to 5 days

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

82088

LOINC Code Information

Test ID Test Order Name Order LOINC Value
ARAV Aldosterone, RAV 1763-2

 

Result ID Test Result Name Result LOINC Value
6348 Aldosterone, RAV 1763-2