Test Code BRAZR Brazil Nut, IgE with Reflex to Brazil Nut Component, IgE, Serum
Ordering Guidance
For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies.
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.6 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Useful For
Evaluation of patients with suspected Brazil nut allergy
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
BRAZX | Brazil Nut Component, IgE, S | No | No |
Testing Algorithm
Testing begins with analysis of Brazil nut-specific total IgE. If the Brazil nut-specific total IgE result is negative (<0.10 kU/L), testing is complete.
If the Brazil nut-specific total IgE result is 0.10 kU/L or more, then the Brazil nut component (Ber e 1) test will be performed at an additional charge.
Special Instructions
Method Name
Fluorescent Enzyme Immunoassay (FEIA)
Reporting Name
Brazil Nut Component Reflex, SSpecimen Type
SerumSpecimen Minimum Volume
0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 90 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
Class |
IgE kU/L |
Interpretation |
0 |
<0.10 |
Negative |
0/1 |
0.10-0.34 |
Borderline/Equivocal |
1 |
0.35-0.69 |
Equivocal |
2 |
0.70-3.49 |
Positive |
3 |
3.50-17.4 |
Positive |
4 |
17.5-49.9 |
Strongly positive |
5 |
50.0-99.9 |
Strongly positive |
6 |
≥100 |
Strongly positive |
Concentrations of 0.70 kU/L or more (class 2 and above) will flag as abnormally high.
Reference values apply to all ages.
Interpretation
When detectable total Brazil nut IgE antibody is present (≥0.10 IgE kUa/L), additional specific component IgE antibody testing will be performed. If a potential specific allergenic Brazil nut component IgE is detectable (≥0.10 IgE kUa/L), an interpretive report will be provided.
When the sample is negative for total Brazil nut IgE antibody (<0.10 IgE kUa/L), further testing for specific Brazil nut component IgE antibodies will not be performed. A negative IgE result for total Brazil nut antibody may indicate a lack of sensitization to the potential Brazil nut allergenic component.
Day(s) Performed
Monday through Friday
Report Available
Same day/1 to 3 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
86003
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
BRAZR | Brazil Nut Component Reflex, S | 6050-9 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
BRAZ1 | Brazil Nut, IgE, S | 6050-9 |
Forms
If not ordering electronically, complete, print, and send an Allergen Test Request (T236) with the specimen.