Test Code BRAZX Brazil Nut Component, IgE, Serum
Specimen Required
Only orderable as a reflex. For more information see BRAZR / Brazil Nut, IgE, with Reflex to Brazil Nut Component, IgE, Serum
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 0.6 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Useful For
Evaluation of patients with suspected Brazil nut allergy to component Ber e 1
Testing Algorithm
If the Brazil nut specific total IgE result is 0.10 kU/L or more, then the Brazil nut component (Ber e 1) test is performed at an additional charge.
Method Name
Only orderable as a reflex. For more information see BRAZR / Brazil Nut, IgE, with Reflex to Brazil Nut Component, IgE, Serum.
Fluorescent Enzyme Immunoassay (FEIA)
Reporting Name
Brazil Nut Component, IgE, SSpecimen Type
SerumSpecimen Minimum Volume
0.4 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 90 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
Only orderable as a reflex. For more information see BRAZR / Brazil Nut, IgE, with Reflex to Brazil Nut Component, IgE, Serum
Class |
IgE kU/L |
Interpretation |
0 |
<0.10 |
Negative |
0/1 |
0.10-0.34 |
Borderline/Equivocal |
1 |
0.35-0.69 |
Equivocal |
2 |
0.70-3.49 |
Positive |
3 |
3.50-17.4 |
Positive |
4 |
17.5-49.9 |
Strongly positive |
5 |
50.0-99.9 |
Strongly positive |
6 |
≥100 |
Strongly positive |
Concentrations of 0.70 kU/L or more (class 2 and above) will flag as abnormally high.
Reference values apply to all ages.
Interpretation
When detectable total Brazil nut IgE antibody is present (≥0.10 IgE kUa/L), additional specific component IgE antibody testing will be performed. If a potential specific allergenic Brazil nut component IgE is detectable (≥0.10 IgE kUa/L), an interpretive report will be provided.
When the sample is negative for total Brazil nut IgE antibody (<0.10 IgE kUa/L), further testing for specific Brazil nut component IgE antibodies will not be performed. A negative IgE result for total Brazil nut antibody may indicate a lack of sensitization to the potential Brazil nut allergenic component.
Day(s) Performed
Monday through Friday
Report Available
Same day/1 to 3 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
86008
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
BRAZX | Brazil Nut Component, IgE, S | 64963-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
IBRAZ | Brazil Nut IgE Ab Interpretation | 69048-7 |
E1BER | Ber e 1 (Brazil Nut), IgE, S | 64963-2 |