Test Code Billings Clinic: 8008 Mayo: PEANT Peanut, IgE with Reflex to Peanut Components, IgE, Serum
Reporting Name
Peanut Component Reflex, SPerforming Laboratory
Mayo Clinic Laboratories in RochesterUseful For
Evaluating patients with suspected peanut allergy
Method Name
Fluorescent Enzyme Immunoassay (FEIA)
Ordering Guidance
For a listing of allergens available for testing, see Allergens - Immunoglobulin E (IgE) Antibodies.
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 2 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Type
SerumSpecimen Minimum Volume
1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 90 days | ||
Ambient | 7 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
Class |
IgE kU/L |
Interpretation |
0 |
<0.10 |
Negative |
0/1 |
0.10-0.34 |
Borderline / Equivocal |
1 |
0.35-0.69 |
Equivocal |
2 |
0.70-3.49 |
Positive |
3 |
3.50-17.4 |
Positive |
4 |
17.5-49.9 |
Strongly positive |
5 |
50.0-99.9 |
Strongly positive |
6 |
≥100 |
Strongly positive |
Concentrations of 0.70 kU/L or more (class 2 and above) will flag as abnormally high.
Reference values apply to all ages.
Interpretation
When detectable total peanut IgE antibody is present (≥0.10 IgE kUa/L), additional specific component IgE antibody testing will be performed. If at least one potential specific allergenic peanut component IgE is detectable (≥0.10 IgE kUa/L), an interpretative report will be provided.
When the sample is negative for total peanut IgE antibody (<0.10 IgE kUa/L), further testing for specific peanut component IgE antibodies will not be performed. Negative IgE results for total peanut antibody may indicate a lack of sensitization to potential peanut allergenic components.
Day(s) Performed
Monday through Friday
Report Available
Same day/1 to 3 daysTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
86003
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
PEANT | Peanut Component Reflex, S | 6206-7 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
PNUT | Peanut, IgE, S | 6206-7 |
Forms
If not ordering electronically, complete, print, and send an Allergen Test Request (T236) with the specimen.
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
PNTCP | Peanut Components, IgE, S | No | No |
Testing Algorithm
Testing begins with analysis of peanut IgE. If peanut IgE is negative (<0.10 kU/L), testing is complete.
If peanut IgE is 0.10 kU/L or greater, then 7 peanut components (Ara h 2, Ara h 1, Ara h 3, Ara h 6, Ara h 8, Ara h 9, and profilin Bet v2) are performed at an additional charge.