Sign in →

Test Code CDUOE Cadmium Occupational Exposure, Random, Urine

Reporting Name

Cadmium Occupat Exp, Random, U

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Useful For

Detecting occupational exposure to cadmium, a toxic heavy metal, using random urine specimens

Method Name

CDOU: Triple -Quadrupole Inductively Coupled Plasma  Mass Spectrometry (ICP-MS/MS)

CRETR: Enzymatic Colorimetric Assay


Specimen Required


Patient Preparation: High concentrations of gadolinium and iodine are known to interfere with most metal tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.

Supplies: Urine Tubes, 10 mL (T068)

Collection Container/Tube: Clean, plastic urine container with no metal cap or glued insert

Submission Container/Tube: Plastic, 10-mL urine tube or clean, plastic aliquot container with no metal cap or glued insert

Specimen Volume: 3 mL

Collection Instructions:

1. Collect urine a random urine specimen.

2. See Metals Analysis Specimen Collection and Transport for complete instructions.


Specimen Type

Urine

Specimen Minimum Volume

1.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Urine Refrigerated (preferred) 28 days
  Frozen  28 days
  Ambient  14 days

Reject Due To

  All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.

Reference Values

CADMIUM/CREATININE:

Biological Exposure Indices (BEI): <5.0 mcg/g creatinine

 

CREATININE:

≥18 years: 16-326 mg/dL

Reference values have not been established for patients who are younger than 18 years of age. 

Interpretation

Urine cadmium levels primarily reflect total body burden of cadmium. Cadmium excretion above 3.0 mcg/g creatinine indicates significant exposure to cadmium.

 

For occupational testing, the OSHA cadmium standard is below 3.0 mcg/g creatinine, and the biological exposure index is 5 mcg/g creatinine.

Day(s) Performed

Monday through Friday

Report Available

2 to 4 days

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

82300

82570

LOINC Code Information

Test ID Test Order Name Order LOINC Value
CDUOE Cadmium Occupat Exp, Random, U 13471-8

 

Result ID Test Result Name Result LOINC Value
CRETR Creatinine, Random, U 2161-8
608892 Cadmium Occupational Exposure 13471-8

Profile Information

Test ID Reporting Name Available Separately Always Performed
CDOU Cadmium Occupational Exposure No Yes
CRETR Creatinine, Random, U No Yes