Sign in →

Test Code CHAGI Trypanosoma cruzi, Technical Interpretation


Specimen Required


Only orderable as part of a profile. For more information see CRUZI / Trypanosoma cruzi (Chagas) Antibody Panel, Serum.


Useful For

Diagnosis of chronic Trypanosoma cruzi infection (Chagas disease)

Method Name

Only orderable as part of a profile. For more information see CRUZI / Trypanosoma cruzi (Chagas) Antibody Panel, Serum.

 

Technical Interpretation

Reporting Name

T. cruzi Interpretation

Specimen Type

Serum

Specimen Minimum Volume

See Specimen Required

Specimen Stability Information

Specimen Type Temperature Time
Serum Frozen 14 days

Reference Values

Only orderable as part of a profile. For more information see CRUZI / Trypanosoma cruzi (Chagas) Antibody Panel, Serum.

 

An interpretive report will be provided.

Interpretation

CHAGS result

CHAGL result

Interpretive comment

Positive

Positive

Antibodies to Trypanosoma cruzi (Chagas disease) detected by two separate methods, suggesting current or past infection. Results should be interpreted alongside clinical presentation and exposure history.

Positive

Negative

Antibodies to Trypanosoma cruzi (Chagas disease) detected by one of two assays. Discordant results can be resolved through submission of a new sample for testing or through additional testing at a public health laboratory.

Positive

Invalid

Submission of a new sample is recommended to resolve discordant results.

Indeterminate

Positive

Antibodies to Trypanosoma cruzi (Chagas disease) detected by one of two assays. Discordant results can be resolved through submission of a new sample for testing or through additional testing at a public health laboratory.

Indeterminate

Negative

Submission of a new sample is recommended to resolve discordant results.

Indeterminate

Invalid

Submission of a new sample is recommended to resolve discordant results.

Negative

Positive

Antibodies to Trypanosoma cruzi (Chagas disease) detected by one of two assays. Discordant results can be resolved through submission of a new sample for testing or through additional testing at a public health laboratory.

Negative

Negative

No antibodies to Trypanosoma cruzi (Chagas disease) detected. False negative results may occur in patients tested within 4 weeks of infection.

Negative

Invalid

Submission of a new sample is recommended to resolve discordant results.

Day(s) Performed

Monday

Report Available

Same day/1 to 8 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

Not Applicable

LOINC Code Information

Result ID Test Result Name Result LOINC Value
CHAGI T. cruzi Interpretation 59464-8