Test Code CSPCF Plasma Cell Proliferative Disorder, Pre-Analysis Cell Sorting, Bone Marrow
Reporting Name
PCPDS Pre-Analysis Cell Sorting, BMPerforming Laboratory
Mayo Clinic Laboratories in RochesterUseful For
Aiding in the diagnosis of new cases of multiple myeloma or other plasma cell proliferative disorders
Sorting plasma cells for fluorescence in situ hybridization analysis
Method Name
Only orderable as a reflex. See PCPDS / Plasma Cell Proliferative Disorder, High Risk with Reflex Probes, Diagnostic FISH Evaluation, Bone Marrow
Flow Cytometric Cell Selection
Specimen Required
Only orderable as a reflex. See PCPDS / Plasma Cell Proliferative Disorder, High Risk with Reflex Probes, Diagnostic FISH Evaluation, Bone Marrow
Specimen Type: Bone marrow
Preferred: Yellow top (ACD solution A or B)
Acceptable: Lavender top (EDTA) or green top (heparin)
Specimen Volume: 4 mL
Collection Instructions:
1. Invert several times to mix bone marrow
2. Send bone marrow specimen in original tube. Do not aliquot.
Specimen Type
Bone MarrowSpecimen Minimum Volume
2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Bone Marrow | Ambient (preferred) | 4 days | |
Refrigerated | 4 days |
Reject Due To
Gross hemolysis | Reject |
Other | Fully clotted |
Reference Values
Only orderable as a reflex. See PCPDS / Plasma Cell Proliferative Disorder, High Risk with Reflex Probes, Diagnostic FISH Evaluation, Bone Marrow
An interpretive report will be provided.
Interpretation
Correlation with clinical, histopathologic and additional laboratory findings is required for final interpretation of these results. The final interpretation of results for clinical management of the patient is the responsibility of the managing physician.
Day(s) Performed
Specimens processed: Monday through Sunday
Results reported: Monday through Friday
Report Available
1 to 7 daysTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
88184-Flow Cytometry; first cell surface, cytoplasmic or nuclear marker
88185 x 5-Flow Cytometry, additional cell surface, cytoplasmic or nuclear marker (each)
LOINC Code Information
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
607684 | PCPDS Pre-Analysis Cell Sort | No LOINC Needed |
607689 | Final Diagnosis | No LOINC Needed |