Test Code ESTS Estradiol, Rapid, Immunoassay, Serum

Reporting Name

Estradiol Rapid, Immunoassay, S

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Useful For

Rapid assessment of ovarian status, including follicle development, for assisted reproduction protocols (eg, in vitro fertilization)

 

Establishing time of ovulation and optimal time for conception

Method Name

Electrochemiluminescent Immunoassay (ECLIA)


Ordering Guidance


This assay is for reproductive assessment (eg, IVF, conception). For other clinical indications, order EEST / Estradiol, Serum.

 

The preferred method for measurement of low serum estradiol concentrations in children, males, and postmenopausal females is liquid chromatography-tandem mass spectrometry (LC-MS/MS), order EEST / Estradiol, Serum.

 

This test should not be used when monitoring estradiol concentrations in patients being treated with Fulvestrant due to possible cross-reactivity. In these patients, estradiol concentrations should be measured using mass spectrometry; order EEST / Estradiol, Serum.



Specimen Required


Patient Preparation: For 12 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Within 2 hours of collection, centrifuge and aliquot serum into a plastic vial.


Specimen Type

Serum

Specimen Minimum Volume

0.4 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Frozen (preferred) 180 days
  Refrigerated  5 days
  Ambient  24 hours

Reject Due To

Gross hemolysis Reject
Gross lipemia OK
Gross icterus OK

Reference Values

Males: 10-40 pg/mL

Females

Premenopausal: 15-350 pg/mL*

Postmenopausal: <10 pg/mL

*Estradiol concentrations vary widely throughout the menstrual cycle

Interpretation

Optimal time for conception is within 48 to 72 hours following the midcycle estradiol peak. Serial specimens must be drawn over several days to evaluate baseline and peak estradiol levels. Low baseline levels and a lack of rise, as well as persistent high levels without midcycle rise, are indicative of anovulatory cycles.

 

For determining the timing of initiation of ovarian stimulation in in vitro fertilization (IVF) studies, low levels before stimulation are critical, as higher values often are associated with poor stimulation cycles. Before final human chorionic gonadotropin (hCG) stimulation at mid-IVF cycle, estradiol concentrations above 2000 to 3000 pg/mL are considered by some IVF specialists to be indicative of an increased likelihood of ovarian hyperstimulation and it may be advisable to consider withholding further hCG stimulation.

 

Estradiol (E2) concentrations below 200 pg/mL following midcycle stimulation (hCG or follicle-stimulating hormone [FSH]) are associated with very low pregnancy success rates.

 

Estradiol concentrations change during the menstrual cycle, as follows:

-less than 50 pg/mL before midfollicular phase

-250 to 500 pg/mL midcycle peak as the follicle matures

-Abrupt decrease after ovulation

-125 pg/mL peak during the luteal phase

 

Estrogen replacement in reproductive-age women should aim to mimic natural estrogen levels as closely as possible. E2 levels should be within the reference range for premenopausal women and luteinizing hormone and FSH should be within the normal range.

Day(s) Performed

Monday through Sunday

Report Available

Same day/1 to 2 days

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

82670

LOINC Code Information

Test ID Test Order Name Order LOINC Value
ESTS Estradiol Rapid, Immunoassay, S 2243-4

 

Result ID Test Result Name Result LOINC Value
ESTS Estradiol Rapid, Immunoassay, S 2243-4