Test Code ETGR Ethyl Glucuronide Screen with Reflex, Random, Urine
Reporting Name
Ethyl Glucuronide Scrn w/Reflex, UPerforming Laboratory
Mayo Clinic Laboratories in RochesterUseful For
Screening and confirmation for drug abuse involving alcohol
Method Name
Immunoassay
Ordering Guidance
For situations where chain of custody is required, a Chain of Custody Kit (T282) is available. For chain-of-custody testing, order ETGX / Ethyl Glucuronide Confirmation, Chain of Custody, Random, Urine.
Additional Testing Requirements
If urine creatinine is required or adulteration of the sample is suspected, the following test should also be ordered, ADULT / Adulterants Survey, Random, Urine.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Plastic urine container
Submission Container/Tube: Plastic, 5 mL tube
Specimen Volume: 5 mL
Collection Instructions:
1. Collect a random urine specimen.
2. No preservative.
Specimen Type
UrineSpecimen Minimum Volume
2.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 28 days | |
Frozen | 28 days | ||
Ambient | 72 hours |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
Negative
Screening cutoff concentration: 500 ng/mL
Interpretation
If the screen result is negative, ethyl glucuronide concentrations were not detected.
If the screen result is positive, then confirmation by liquid chromatography tandem mass spectrometry will be performed.
A positive interpretation will be given if either the ethyl glucuronide (EtG) result is greater than or equal to 250 ng/mL and/or the ethyl sulfate (EtS) is greater than or equal to 100 ng/mL.
A "high" positive (ie, >1000 ng/mL) may indicate:
-Heavy drinking on the same day or previously (ie, previous day or 2).
-Light drinking the same day
A "low" positive (ie, 500-1000 ng/mL) may indicate:
-Previous heavy drinking (ie, previous 1 3 days).
-Recent light drinking (ie, past 24 hours).
-Recent intense "extraneous" exposure (ie, within 24 hours or less).
A "very low" positive (ie, 100-500 ng/mL) may indicate:
-Previous heavy drinking (ie, 1-3 days)
-Previous light drinking (ie, 12-36 hours).
-Recent "extraneous" exposure.(2)
Day(s) Performed
Monday through Saturday
Report Available
Same day/1 to 2 daysTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
80307
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
ETGR | Ethyl Glucuronide Scrn w/Reflex, U | 58375-7 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
63420 | Ethyl Glucuronide Screen, U | 58375-7 |
Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.
Profile Information
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
ETGS | Ethyl Glucuronide Screen, U | Yes | Yes |
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
ETGC | Ethyl Glucuronide Confirmation, U | Yes | No |
Testing Algorithm
Testing begins with a screening assay. If the screen is positive, then the liquid chromatography tandem mass spectrometry confirmation with quantification will be performed at an additional charge.