Sign in →

Test Code FCQBA Circulating Immune Complex, C1q Binding

Reporting Name

CIC, C1q Binding

Performing Laboratory

ARUP Laboratories

Method Name

Semi-Quantitative Enzyme-Linked Immunosorbent Assay


Specimen Required


Collection Container/Tube: Red Top or SST

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

 

Collection Instructions: Draw blood in a plain, red-top tube(s). (Serum gel tube is acceptable.) Allow complete clotting of red blood cells (up to 1 hour), then separate serum from cells withing 30 minutes and freeze immediately. Send 1 mL of serum frozen in a plastic vial.

 

Note: Critical frozen. Separate specimens must be submitted when multiple tests are ordered.

 


Specimen Type

Serum

Specimen Minimum Volume

0.3 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Frozen 14 days

Reject Due To

Gross hemolysis: reject
Thawing: Warm reject; Cold reject
Other: Non-frozen specimen
   

Reference Values

0.0-3.9 ug Eq/mL

Interpretation

Less than or equal to 3.9 ug Eq/mL is considered negative for circulating complement binding immune complexes.

 

Circulating immune complexes may be found without any evident pathology and positive results do not necessarily implicate the immune complex in a disease process.

Day(s) Performed

Saturday, Monday, and Thursday

Report Available

4 to 15 days

CPT Code Information

86332

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FCQBA CIC, C1q Binding 27831-7

 

Result ID Test Result Name Result LOINC Value
Z2636 CIC, C1q Binding 27831-7