Sign in →

Test Code GAL1 GALAD Score, Serum

Reporting Name

GALAD Model Score

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Useful For

Calculation of the GALAD (gender, age, alpha-fetoprotein L3% [AFP-L3], AFP, des-gamma-carboxy prothrombin) model score for hepatocellular carcinoma development in patients with chronic liver disease

Method Name

Only orderable as part of a profile. For more information see HCCGS / Hepatocellular Carcinoma Risk Panel with GALAD Score, Serum

 

Gender, Age, Alpha-fetoprotein L3% (AFP-L3), AFP, Des-gamma-carboxy prothrombin (GALAD) Model Score Calculation


Specimen Required


Only orderable as part of a profile. For more information see HCCGS / Hepatocellular Carcinoma Risk Panel with GALAD Score, Serum.

 

Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube: 

Preferred: Serum gel  

Acceptable:  Red top 

Submission Container/Tube: Plastic vial 

Specimen Volume: 0.5 mL 

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Type

Serum

Specimen Minimum Volume

0.25 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Frozen (preferred) 90 days
  Refrigerated  5 days

Reject Due To

Gross hemolysis Reject
Gross lipemia OK
Gross icterus OK

Reference Values

Only orderable as part of a profile. For more information see HCCGS / Hepatocellular Carcinoma Risk Panel with GALAD Score, Serum

 

Not applicable

Interpretation

Higher GALAD (gender, age, AFP-L3, AFP, des-gamma-carboxy prothrombin) model scores correlate with increased risk of hepatocellular carcinoma (HCC). The area under the curve (AUC) of a receiver operating characteristic (ROC) curve of the GALAD score was 0.95 for all HCC detection and 0.92 for the detection of early-stage HCC. Additionally, the AUC of the GALAD score (0.95) was higher than that of ultrasound alone for all HCC detection (AUC of 0.82, P <0.01).

 

The sensitivity and specificity performance characteristics of the GALAD score for HCC will be influenced by the selected GALAD score cut-off. For example, at an optimal AUC cutoff of -0.76, the GALAD score had 91% sensitivity and 85% specificity for HCC detection. At a more specific GALAD score cutoff of 0.88, the observed sensitivity was 80% for HCC detection, with an observed specificity of 97%.

 

The GALAD model was developed and validated in patient cohorts with a prevalence of HCC ranging from 35% to 49%. The performance of the model may be altered in populations with different HCC prevalence. In addition, the clinical performance of the GALAD score varies by etiology of HCC and, therefore, may be different in different regions of the world.

Day(s) Performed

Monday, Wednesday, Friday

Report Available

Same day/1 to 4 days

Test Classification

Not Applicable

LOINC Code Information

Test ID Test Order Name Order LOINC Value
GAL1 GALAD Model Score 96450-2

 

Result ID Test Result Name Result LOINC Value
GAL1 GALAD Model Score 96450-2