Test Code HPFLU Influenza Virus Type A and Type B and Respiratory Syncytial Virus (RSV) RNA, Molecular Detection, PCR, Varies
Specimen Required
Preferred:
Specimen Type: Nasopharyngeal swab
Container/Tube: Sterile container with viral transport media
Specimen Volume: Entire specimen with a minimum of 1.5 mL (maximum 3 mL) of transport media.
Collection Instructions:
1. Collect specimen by swabbing back and forth over mucosa surface to maximize recovery of cells.
2. Swab must be placed into viral transport media (eg, M4-RT, M4 or M5), saline, or phosphate buffered saline (PBS). Media should not contain guanidine thiocyanate (GTC).
Specimen Type: Bronchoalveolar lavage fluid
Container/Tube: Sterile container
Specimen Volume: 0.6 mL
Additional Information: Do not aliquot into viral transport media.
Acceptable:
Specimen Type: Oropharyngeal (throat) swab, nasal mid-turbinate, or nares/nasal swab
Supplies:
-Culturette (BBL Culture Swab) (T092)
-Mid Turbinate (MT) Swab (FLOQSwab/COPAN) (T864)
-Swab, Sterile Polyester (T507)
Container/Tube: Sterile container with transport media
Specimen Volume: Entire specimen with a minimum of 1.5 mL (maximum 3 mL) of transport media.
Preferred: BBL Culture Swab, COPAN Mid-turbinate Swab
Acceptable: Dacron-tipped swab with plastic handle
Collection Instructions: Swab must be placed into viral transport media (eg, M4-RT, M4, or M5), saline, or PBS. Media should not contain guanidine thiocyanate (GTC).
Specimen Type: Bronchial washings, endotracheal aspirate, sputum
Container/Tube: Sterile container
Specimen Volume: 0.6 mL
Additional Information: Do not aliquot into viral transport media.
Useful For
Simultaneous detection of influenza A virus, influenza B virus, and respiratory syncytial virus in upper or lower respiratory tract specimens from individuals with flu-like illnesses
Testing Algorithm
For information see Coronavirus Disease 2019 (COVID-19), Influenza, and Respiratory Syncytial Virus Testing Algorithm.
Method Name
Multiplex Reverse Transcriptase, Real-Time Polymerase Chain Reaction (RT-qPCR)
Reporting Name
Influenza A/B and RSV, PCR, VariesSpecimen Type
VariesSpecimen Minimum Volume
Upper respiratory tract swab: See Specimen Required; Lower respiratory specimens: 0.3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Frozen (preferred) | 14 days | |
Refrigerated | 72 hours |
Reject Due To
Bloody specimen Calcium alginate-tipped swab Wooden shaft swab Dry swab Glass transport media tubes Transport swab containing gel or charcoal additive Sample tubes containing guanidine isothiocyanate, guanidine thiocyanate, or guanidine hydrochloride |
Reject |
Reference Values
Undetected
Interpretation
A "Detected" (positive) test result indicates that the patient is presumptively infected with the indicated virus. The test does not indicate the stage of infection. Rarely, more than one virus may be detected from the same patient specimen. Laboratory test results should always be considered in the context of clinical observations and epidemiologic data in making a final diagnosis.
An “Undetected†(negative) test result suggests that the patient is not infected with influenza A virus, influenza B virus, or respiratory syncytial virus (RSV).
An "Inconclusive" result indicates that the presence or absence of influenza A virus, influenza B virus, and RSV in the specimen could not be determined with certainty after repeat testing in the laboratory, possibly due to real-time, reverse transcription polymerase chain inhibition. Submission of a new specimen for testing is recommended.
Day(s) Performed
Monday through Sunday
Report Available
Same day/1 to 2 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
87631
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
HPFLU | Influenza A/B and RSV, PCR, Varies | 92143-7 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
HPFLS | Influenza A/B and RSV, Source | 31208-2 |
610412 | Influenza A virus PCR | 92142-9 |
610413 | Influenza B virus PCR | 92141-1 |
610414 | Respiratory Syncytial Virus, PCR | 92131-2 |
Forms
If not ordering electronically, complete, print, and send an Microbiology Test Request (T244) with the specimen.