Test Code HSTNI Troponin I, High Sensitivity, Plasma
Reporting Name
Troponin I, High Sensitivity, PPerforming Laboratory
Mayo Clinic Laboratories in RochesterUseful For
Excluding the diagnosis of acute coronary syndromes
Explaining troponin T elevations related to skeletal myopathy and/or assay interferences
Method Name
Electrochemiluminescence Immunoassay
Specimen Required
Collection Container/Tube:
Preferred: Mint green top (lithium heparin gel)
Acceptable: Green top (lithium heparin)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Plasma gel tube should be centrifuged within 2 hours of collection.
2. Green-top tube should be centrifuged, and the plasma aliquoted into a plastic vial within 2 hours of collection.
Specimen Type
PlasmaSpecimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma | Frozen (preferred) | 180 days | |
Refrigerated | 48 hours | ||
Ambient | 4 hours |
Reject Due To
Gross hemolysis | Reject |
Reference Values
Males ≥18 years: ≤20 ng/L
Females ≥18 years: ≤15 ng/L
Reference values have not been established for patients younger than 18 years old.
Interpretation
Elevations in cardiac troponin T (cTnT) can be due to skeletal muscle disease and not cardiac disease in certain circumstances. One way to unmask such elevations is to measure cardiac troponin I (cTnI), which will be normal in that situation. In addition, at times there are interferences that can cause spurious increases or decreases in cTnT values. Conceptually, these same interferences can occur with cTnI but in any given case, the likelihood of having both assays be confounded in that way is highly unusual. Thus, potential false-positive results would be unmasked by a normal cTnI and false-negative results by an elevated value.
Day(s) Performed
Monday, Wednesday, Friday
Report Available
2 to 3 daysTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
84484
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
HSTNI | Troponin I, High Sensitivity, P | 89579-7 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
HSTNI | Troponin I, High Sensitivity, P | 89579-7 |
Forms
If not ordering electronically, complete, print, and send a Cardiovascular Test Request Form (T724) with the specimen.