Sign in →

Test Code IETG Interference Evaluation Heterophile, Thyroglobulin Tumor Marker, Serum


Ordering Guidance


If interference or heterophile testing is not required, order HTG2 / Thyroglobulin, Tumor Marker, Serum.

 

For fine-needle aspirate specimens, order TFNAB / Thyroglobulin, Tumor Marker, Fine-Needle Aspiration Biopsy Needle Wash.



Specimen Required


Patient Preparation: For 12 hours before specimen collection do not take multivitamins or dietary supplements containing biotin (vitamin B7), which is commonly found in hair, skin, and nail supplements and multivitamins.

Collection Container/Tube: Red top (serum gel/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 2.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Useful For

Evaluation of suspected interference from heterophile antibodies causing a falsely elevated thyroglobulin result

Profile Information

Test ID Reporting Name Available Separately Always Performed
TGII TG, Interference Interpretation No Yes
TGQN Thyroglobulin, Tumor Marker, S Yes, (Order HTG2) Yes
TGABI Thyroglobulin Antibody, S Yes, (Order HTG2) Yes
TGMS Thyroglobulin, Mass Spec., S Yes Yes

Testing Algorithm

Heterophile antibody evaluation consists of comparison of thyroglobulin (Tg) concentrations obtained by immunoassay with the following:

-Tg concentrations following pretreatment with commercial heterophile blocking reagents

-Tg concentrations obtained by mass spectrometry

-Tg concentrations obtained by serial dilutions of the sample

In all samples the presence of anti-thyroglobulin antibodies are evaluated.

Method Name

TGQN/TGABI: Immunoenzymatic Assay

TGMS: Tryptic Protein Fragmentation, purified with Immunocapture, Analysis by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS)

(This service is performed pursuant to an agreement with SISCAPA Assay Technologies Inc. covering US Patent 7,632,686)

TGII: Medical Interpretation

Reporting Name

Interference Eval, Heterophile, TG

Specimen Type

Serum Red

Specimen Minimum Volume

2 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Red Refrigerated (preferred) 7 days
  Frozen  30 days
  Ambient  72 hours

Reject Due To

Gross hemolysis Reject
Gross lipemia OK
Gross icterus Reject

Reference Values

THYROGLOBULIN TUMOR MARKER

Athyrotic: <0.1 ng/Ml

 

Intact thyroid: ≤33 ng/mL

THYROGLOBULIN, MASS SPECTROMETRY

Athyrotic: <0.2 ng/mL

Healthy individuals with intact, functioning thyroid: ≤33 ng/mL

 

THYROGLOBULIN ANTIBODY

<1.8 IU/mL

Reference values apply to all ages.

Interpretation

Specimens are evaluated for the presence of potential interfering anti-thyroglobulin (TgAb) and heterophile antibody interference in the Beckman Access thyroglobulin (Tg) immunoassay. While the presence of TgAb can result in falsely low Tg concentrations in the Beckman immunoassay, the presence of heterophile antibodies can result in falsely elevated Tg concentrations in the Beckman immunoassay. Following investigation of the presence of TgAb, heterophile antibody evaluation consists of pretreatment with commercial heterophile antibody blocking reagents, serial dilutions of the sample, and testing on an alternate platform generally unaffected by the presence of heterophile antibodies or TgAb (ie, Tg liquid chromatography-tandem mass spectrometry [Tg-MS]). The presence of heterophile antibody interference in the Beckman Access Tg immunoassay is not suspected when the results from the pretreatment, serial dilutions, and the alternative platform (Tg-MS) agree with the original result.

 

The presence of heterophile antibody interference in the Beckman Access Tg immunoassay is suspected when 1 or more of the following are observed: a significant decrease in Tg concentration (>20%) upon treatment of the sample with heterophile antibody blocking reagents, lack of linearity upon serial dilutions, or a significant difference in Tg concentration on the alternate platform (Tg-MS). When a heterophile antibody interference affecting the Beckman Access immunoassay is suspected, the Tg result from this assay is considered false positive and should not be used in clinical management.

 

Thyroglobulin Antibody:

TgAb may interfere with the measurement of Tg. TgAb should be measured in conjunction with every measurement of serum Tg to rule out potential interference. Anti-Tg antibodies greater or equal to 1.8 IU/mL are likely to cause interference in the Tg immunoassay. In the Beckman Access Tg immunoassay utilized in this interference evaluation, the presence of TgAb is most likely to cause a reduction in measured Tg concentrations. Measurement of Tg by mass spectrometry is not affected by the presence of TgAb.

Day(s) Performed

Monday through Saturday

Report Available

3 to 6 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

84432

86800

84432

LOINC Code Information

Test ID Test Order Name Order LOINC Value
IETG Interference Eval, Heterophile, TG 101626-0

 

Result ID Test Result Name Result LOINC Value
62749 Thyroglobulin, Mass Spec., S 3013-0
35998 Interpretation 59462-2
TGABI Thyroglobulin Antibody, S 56536-6
TGQN Thyroglobulin, Tumor Marker, S 96460-1
TGIF TG, Interference Heterophile 101627-8
TGIN TG, Interpretation 101628-6