Test Code IN16Q CBFB::MYH11 Inversion(16), Quantitative Detection and Minimal Disease Risk Monitoring, qRT-PCR, Varies
Shipping Instructions
1. Refrigerated specimens must arrive within 5 days of collection, and ambient specimens must arrive within 3 days of collection.
2. Collect and package specimen as close to shipping time as possible.
Necessary Information
The following information is required:
1. Pertinent clinical history
2. Date of collection
3. Specimen source (blood or bone marrow)
Specimen Required
Submit only 1 of the following specimens:
Specimen Type: Blood
Container/Tube: Lavender top (EDTA) or yellow top (ACD-B)
Specimen Volume: 10 mL
Collection Instructions:
1. Invert several times to mix blood.
2. Send whole blood specimen in original tube. Do not aliquot.
3. Label specimen as blood.
Specimen Type: Bone marrow
Container/Tube: Lavender top (EDTA) or yellow top (ACD-B)
Specimen Volume: 4 mL
Collection Instructions:
1. Invert several times to mix bone marrow.
2. Send bone marrow specimen in original tube. Do not aliquot.
3. Label specimen as bone marrow.
Forms
1. Hematopathology Patient Information (T676)
2. If not ordering electronically, complete, print, and send an Hematopathology/Cytogenetics Test Request (T726) with the specimen.
Useful For
Detection of CBFB::MYH11 gene fusion in patients recently diagnosed with acute myeloid leukemia (AML)
Minimal residual disease monitoring during the clinical and therapeutic course of patients with AML
Method Name
Quantitative Real-Time Reverse Transcription Polymerase Chain Reaction (qRT-PCR)
Reporting Name
Inv(16); CBFB-MYH11, Quant, VSpecimen Type
VariesSpecimen Minimum Volume
Blood: 8 mL; Bone marrow: 2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Refrigerated (preferred) | 5 days | |
Ambient | 72 hours |
Reject Due To
Gross hemolysis | Reject |
Bone marrow core biopsies Paraffin-embedded bone marrow clots Slides Paraffin shavings Moderately to severely clotted |
Reject |
Reference Values
An interpretive report will be provided.
Interpretation
The assay is reported in the form of a normalized ratio of CBFB::MYH11 fusion transcript to the control gene ABL1 expressed as a percentage, which is an estimate of the level of CBFB::MYH11 fusion RNA present in the specimen, expressed in relation to the level of RNA from an internal control gene (ABL1). The normalized ratio has no units but is directly related to the level of CBFB::MYH11 detected (ie, larger numbers indicate higher relative levels of CBFB::MYH11, and smaller numbers indicate lower levels). A relative expression value minimizes variability in the RNA levels and cell numbers measured in separate specimens tested at different times.
The precision of the quantitative assay is excellent, but interassay variability can occur such that result changes should not be considered significant if 2 single measurements differ by less than 0.5 log. More critical results, such as a change in the status of positivity or greater or equal to 1 log increase between 2 positive samples should be repeated on a separate specimen with appropriate time interval to verify the result.
Day(s) Performed
Monday through Saturday
Report Available
4 to 8 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
81401-CBFB-MYH11
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
IN16Q | Inv(16); CBFB-MYH11, Quant, V | 101377-0 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
MP057 | Specimen Type | 31208-2 |
610267 | Interpretation | 59465-5 |
614375 | Signing Pathologist | 19139-5 |