Test Code PIPA Pipecolic Acid, Serum
Reporting Name
Pipecolic Acid, SPerforming Laboratory
Mayo Clinic Laboratories in RochesterUseful For
Differentiating between disorders of peroxisomal biogenesis (eg, Zellweger syndrome) and disorders with loss of a single peroxisomal function
Detecting abnormal elevations of pipecolic acid in serum
Method Name
Gas Chromatography Mass Spectrometry (GC-MS)
Necessary Information
Patient's age is required.
Specimen Required
Patient Preparation: Fasting 12 hours or more. (Collect specimens from infants and small children just before next feeding)
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1.5 mL
Collection Instructions: Centrifuge and aliquot serum into plastic vial.
Specimen Type
SerumSpecimen Minimum Volume
1 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Frozen (preferred) | 94 days | |
Refrigerated | 14 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
<6 months: ≤6.0 nmol/mL
6 months-<1 year: ≤5.9 nmol/mL
1-17 years: ≤4.3 nmol/mL
≥18 years: ≤7.4 nmol/mL
Interpretation
Elevated pipecolic acid levels are seen in disorders of peroxisomal biogenesis; normal levels are seen in disorders with loss of a single peroxisomal function.
Abnormal levels of pipecolic acid should be interpreted together with the results of other biochemical markers of peroxisomal disorders, such as plasma C22-C26 very long-chain fatty acids, phytanic acid, and pristanic acid (POX / Fatty Acid Profile, Peroxisomal [C22-C26], Serum); red blood cell plasmalogens (PGRBC / Plasmalogens, Blood); and bile acid intermediates (BAIPD / Bile Acids for Peroxisomal Disorders, Serum).
Day(s) Performed
Tuesday
Report Available
3 to 9 daysTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
82542
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
PIPA | Pipecolic Acid, S | 32334-5 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
81326 | Pipecolic Acid, S | 32334-5 |
29962 | Interpretation | 59462-2 |
29964 | Reviewed By | 18771-6 |
Forms
If not ordering electronically, complete, print, and send a Biochemical Genetics Test Request (T798) with the specimen.
Special Instructions
Testing Algorithm
For more information see Epilepsy: Unexplained Refractory and/or Familial Testing Algorithm